porto-functionality domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/qszqihte/public_html/wp-includes/functions.php on line 6170Special Order 7-14 Day Delivery
]]>Voltage: 250
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 53-64
Model BC53 start capacitor.
Single phase motors rely on a start capacitor to get the motor turning. If there is a problem with this capacitor, the motor may hum but not turn the pump shaft which spins the impeller. One possible cause may be a bad start capacitor.
For Waterway capacitor and other pump brand start and run caps, see them all Canada’s The Hot Tub Superstore.
]]>Voltage: 250
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 64-77
Model BC64 start capacitor.
Single phase motors rely on a start capacitor to get the motor turning. If there is a problem with this capacitor, the motor may hum but not turn the pump shaft which spins the impeller. One possible cause may be a bad start capacitor.
For Waterway capacitor and other pump brand start and run caps, see them all Canada’s The Hot Tub Superstore.
]]>Voltage: 125
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 270-324
Model BC270 start capacitor.
Single phase motors that use a start capacitor to get the motor started may not work properly if the start cap is bad.
For a new start capacitors and other pump brand start and run caps for your spa, order online at Canada’s The Hot Tub Superstore or call our customer service line for more information.
]]>Voltage: 125
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 216-259
Model BC216 start capacitor.
Single phase motors use a start capacitor to get the motor started. If there is a problem with this start capacitor on a spa pump, it may not work at all.
For a Waterway start cap, Ultra Jet start capacitors and other pump brand start and run caps, get them here at Canada’s The Hot Tub Superstore or call our customer service line for more information.
]]>Voltage: 125
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 145-175
Model BC145 start capacitor.
Single phase motors rely on a start capacitor to get the motor turning. If there is a problem with this capacitor, the motor may hum but not turn the pump shaft which spins the impeller. One possible cause may be a bad start capacitor.
For Waterway capacitor and other pump brand start and run caps, see them all Canada’s The Hot Tub Superstore.
]]>Voltage: 125
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 161-193
Model BC161 start capacitor.
Single phase motors may have a start capacitor to get the motor turning. If there is a problem with this capacitor, the pump may not work at all. One possible cause may be a bad start capacitor.
For a Waterway start capacitor and other pump brand start and run caps, get them all Canada’s The Hot Tub Superstore.
]]>Voltage: 125
Length 2 3/4″
Diameter: 1 7/16″
Type: Start Capacitor for hot tub pumps
MFD 189-227
Model BC189 start capacitor.
Single phase motors can use a start capacitor to get the motor started. If there is a problem with this start capacitor otherwise called a start cap, the pump may not work at all.
For a Waterway start cap, Ultra Jet start capacitor and other pump brand start and run caps, find them here at Canada’s The Hot Tub Superstore or call our customer service line for more info.
]]>Voltage: 370
1-3/4″dia x 2-7/8L”; OE# 5VR0303
Model RD30 run capacitor.
Run or start caps may not hold a charge or even have physical characteristics of damage or lost dielectric. In most cases of capacitor problems, there is a physical indication on or near the cap that something is wrong. Be careful when working on capacitors because even when the power is off, they store electricity and can cause a shock.
For a new run and start capacitors for your spa, order online at Canada’s The Hot Tub Superstore, send us an email at sales@thehottubsuperstore.com or call our customer service telephone number for more information.
]]>Voltage: 370
Length 2″
Diameter: 3 3/4″
Type: Run Capacitor for hot tub pumps
Microfarad Rating: 50
Model RD50 run capacitor.
Run or start caps may not hold a charge when not working properly. In most cases of capacitor problems on spa pumps, there is a physical indication on or near the cap that something is wrong such as oozing dielectric fluid. Take care when working on capacitors because even when the power is off, they store electricity and can cause a shock. Only qualified persons should attempt any work on electrical devices.